L2 C x x x
||
TO C
A
LIBR
A
TE SELECT
L2 M x x x
||
HE
A
DER HE IGHT
L2 M x x x
||
HE
A
DER T I LT
L1 M x x x
||
HE
A
DER FLO
A
T
L2 M x x x
||
EX I T C
A
L? NO/ YES TO C
A
LIBR
A
TE SELECT
L1 Cx xx
||
DI
A
GNOS T I C MOD E?
L2 Mx x x
||
N O / Y E S T R
A
CTOR SETUP?
L1 C x x x
||
V
I EW ERROR CODES?
L2 M x x x
||
NO / YES ENTER SENSOR SETUP?
L1 C x x x
||
V
IEW TR
A
CTOR CODES?
||
L2 M x x x
||
NO/ YES
V
IEW ENGINE CODES?
L1 1
||
1234. 5 HRS 123
||
L2 E 4 7
||
SENSOR
V
OLTS LOW
L1 2
||
1230. 5 HRS 123
||
L2 E 7 1
||
LOW HYDR
A
UL IC O I L
L1 C x x x
||
EXIT TR
A
CTOR CODES?
L2 M x x x
||
NO/ YES
L1 C x x x
||
V
I EW ENG I NE CODES?
L2 M x x x
||
NO / YES ENTER SENSOR SET UP ?
L1 1
||
1234. 5 HRS 123
||
L2 4 4 9
||
FUEL PRESSURE H I GH
L1 C x x x
||
EX I T ENG I NE CODES?
L2 M x x x
||
NO/ YES
L1 C x x x
||
EXIT ERROR CODES?
L2 M x x x
||
NO/ YES
V
IEW TR
A
CTOR CODES ?
L1 C x x x
||
ENTER SENSOR SETUP?
L2 M x x x
||
N O / Y E S R E
A
D SENSOR I NPUT S?
L1 C x x x
||
KN I F E SPEED SENSOR
L2 M x x x
||
EN
A
BLE / D I S
A
BLE
L1 C x x x
||
REEL SPEED SENSOR
L2 M x x x
||
EN
A
BLE / D I S
A
BLE
L1 C x x x
||
HE
A
DER HT SENSOR
L2 M x x x
||
EN
A
BLE / D I S
A
BLE
L1 C x x x
||
HE
A
DER T I LT SENSOR
L2 M x x x
||
EN
A
BLE / D I S
A
BLE
L1 C x x x
||
HE
A
DER FLO
A
T SENSOR
L2 M x x x
||
EN
A
BLE / D I S
A
BLE
L1 C x x x
||
O
V
ERLO
A
DPRESSURE
L2 M x x x
||
EN
A
BLE / D I S
A
BLE
L1 C x x x
||
HYD O I L T EMP SENSOR
L2 M x x x
||
EN
A
BLE / D I S
A
BLE
L1 C x x x
||
EX I T SENSOR SETUP?
L2 M x x x
||
NO / YES KN I FE SPEED SENSOR
L1 C x x x
||
RE
A
D SENSOR INPUTS?
L2 M x x x
||
N O / Y E S
A
CT I
V
A
TE FUNCT IONS?
L1 C x x x
||
SENSOR I NPUT
L2 M x x x
||
HDR HE I GHT 3 . 5 9
V
L1 C x x x
||
SENSOR I NPUT
L2 M x x x
||
HDR
A
NGL E 1 . 8 4
V
L1 C x x x
||
SENSOR I NPUT
L2 M x x x
||
2.45
V
FLO
A
T2.84
V
L1 C x x x
||
SENSOR I NPUT
L2 M x x x
||
KN I FE SPEED 1 23 HZ
L1 C x x x
||
SENSOR I NPUT
L2 M x x x
||
REEL SPEED 12 3 HZ
If "NO" then
j
um
p
to:
If "NO" then
j
um
p
to:
The last 10 distinct error codes are stored.
The operator can select each sensor and
selectively enable or disable the sensor. This
can be used to disable a failed sensor to
eliminate false or erratic display readings.
If "NO" then
j
um
p
to:
Select any of the sensors by using the turn signal switches to
cycle through the choices. Pressing SELECT will take the
operator to the calibration menu for that particular sensor. NO
is the default for EXIT CAL?. If "NO" then jump to:
If "NO" then
j
um
p
to:
If "NO" then
j
um
p
to:
If "NO" then
j
um
p
to:
The last 10 distinct error codes are stored
along with the code #, Exxx, engine hours and
number of occurrences. The "arrow" keys are
used to cycle between codes.
If "NO" then jump to the first error code logged.
If "NO" then jump to the first engine error code
lo
gg
ed.
For diagnostic purposes each sensors input
signal can be read. This helps in determining
how each sensor is operating and if the proper
output voltages are being received by the
control system.
If "NO" then
j
um
p
to:
If "NO" then
j
um
p
to:
When "SELECT" is pressed the program goes
to the EXIT SENSOR SETUP? menu
selection.
NOTE: The oil temp. readout applies to the
M205 model with the Sensata oil temp. sensor.